P91 Ramp Soak Controller Specification
Power |
90 - 250 VAC, 47 - 63 Hz, 12VA, 5W maximum |
11 - 26 VAC / VDC, SELV, Limited Energy, 12VA, 5W maximum |
Signal Input |
|
Resolution |
18 bits |
Sampling Rate |
5 times / second |
Maximum Rating |
-2 VDC minimum, 12 VDC maximum( 1 minute for mA input ) |
Temperature Effect |
±1.5
uV/ °C for all inputs except mA input |
Sensor Lead Resistance Effect |
T/C:
0.2uV/ohm |
Burn-out Current |
200nA |
Common Mode Rejection Ratio ( CMRR ) |
120dB |
Normal Mode Rejection Ratio ( NMRR ) |
55dB |
Sensor Break Detection |
Sensor
open for TC, RTD and mV inputs, |
Sensor Break Responding Time |
Within
4 seconds for TC, RTD and mV inputs, |
Input |
|||
Type |
Range |
Accuracy@ 25 °C |
Input Impedance |
J |
-120 ~ 1000 °C (-184 ~ 1832 °F) |
±2 °C |
2.2MΩ |
K |
-200 ~ 1370 °C (-328 ~ 2498°F) |
±2 °C |
2.2MΩ |
T |
-250 ~ 400°C (-418 ~ 752°F) |
±2 °C |
2.2MΩ |
E |
-100 ~ 900 °C (-148 ~ 1652 °F) |
±2 °C |
2.2MΩ |
B |
0 ~ 1800 °C (32 ~ 3272 °F) |
±2 °C (200°C - 1800°C) |
2.2MΩ |
R |
0 ~ 1767.8 °C (32 ~ 3214 °F) |
±2 °C |
2.2MΩ |
S |
0 ~ 1767.8 °C (32 ~ 3214 °F) |
±2 °C |
2.2MΩ |
N |
-250 ~ 1300 °C (-418 ~ 2372 °F) |
±2 °C |
2.2MΩ |
L |
-200 ~ 900 °C (-328 ~ 1652 °F) |
±2 °C |
2.2MΩ |
PT100 (DIN) |
-210 ~ 700 °C (-346 ~ 1292 °F) |
±0.4°C |
1.3KΩ |
PT100 (JIS) |
-200 ~ 600 °C (-328 ~ 1112 °F) |
±0.4°C |
1.3KΩ |
mV |
-8 ~ 70mV |
±0.05% |
2.2MΩ |
mA |
-3 ~ 27mA |
±0.05% |
70.5Ω |
V |
-1.3 ~ 11.5V |
±0.05% |
650KΩ |
Output 1 / Output 2 |
|
Relay Rating |
2A/240 VAC, life cycles 200,000 for resistive load |
Pulsed Voltage |
Source Voltage 5V, current limiting resistance 66Ω . |
Output |
|||
Type |
Zero Tolerance |
Span Tolerance |
Load Capacity |
4-20 mA |
3.6-4 mA |
20-21 mA |
500Ω max. |
0-20 mA |
0 mA |
20-21 mA |
500Ω max. |
0-5 V |
0 V |
5-5.25 V |
10KΩ min. |
1-5 V |
0.9-1 V |
5-5.25 V |
10KΩ min. |
0-10 V |
0 V |
10-10.5 V |
10KΩ min. |
Linear Output |
|
Resolution |
15 bits |
Output Regulation |
0.02 % for full load change |
Output Settling Time |
0.1 sec. ( stable to 99.9 % ) |
Isolation Breakdown Voltage |
1000 VAC |
Temperature Effect |
±0.01 % of SPAN / °C |
Triac ( SSR ) Output |
|
Rating |
1A / 240 VAC |
Inrush Current |
20A for a cycle |
Min. Load Current |
50 mA rms |
Max. Off-state Leakage |
3 mA rms |
Max. On-state Voltage |
1.5V rms |
Insulation Resistance |
1000 Mohms min. at 500 VDC |
Dielectric Strength |
2500 VAC for 1 minute |
DC Voltage Supply characteristics(Install at Output2) |
||||
Type |
Tolerance |
Max. Output Current |
Ripple Voltage |
Isolation Brrifer |
20V |
±1V |
25mA |
0.2Vp-p |
500VAC |
12V |
±0.6V |
40mA |
0.1Vp-p |
500VAC |
5V |
±0.25V |
80mA |
0.05Vp-p |
500VAC |
Alarm |
|
Alarm Relay |
Form C,Max. rating 2A/240VAC, life cycles 200,000 for resistive load. |
Alarm Functions |
Dwell
timer, |
Alarm Mode |
Normal, Latching, Hold, Latching / Hold. |
Dwell Timer |
0.1 - 4553.6 minutes |
Data Communication |
|
Interface |
RS-232 ( 1 unit ), RS-485 ( up to 247 units ) |
Protocol |
Modbus Protocol RTU mode |
Address |
1 - 247 |
Baud Rate |
2.4 ~ 38.4 Kbits/秒 |
Parity Bit |
None, Even or Odd |
Stop Bit |
1 or 2 bits |
Communication Buffer |
64 bytes |
Analog Retransmission |
|
Output Signal |
4-20 mA, 0-20 mA, 0-1V, 0-5V, 1-5V, 0-10V |
Resolution |
15 bits |
Accuracy |
±0.05 % of span ±0.0025 %/ °C |
Load Resistance |
0 - 500 ohms ( for current output ),10 K ohm minimum ( for voltage output ) |
Output Regulation |
0.01 % for full load change |
Output Settling Time |
0.1 sec. (stable to 99.9 % ) |
Isolation Breakdown Voltage |
1000 VAC min. |
Integral Linearity Error |
±0.005 % of span |
Temperature Effect |
±0.0025 % of span/ °C |
Saturation Low |
0 mA ( or 0V ) |
Saturation High |
22.2 mA ( or 5.55V, 11.1V min. ) |
Linear Output Range |
0
- 22.2mA(0-20mA or 4-20mA), |
User Interface |
Dual 4-digit LED Displays |
Keypad |
4 keys |
Programming Port |
For automatic setup, calibration and testing |
Communication Port |
RS-232 and RS-485 |
Control Mode |
|
Output 1 |
Reverse ( heating ) or direct ( cooling )action |
Output 2 |
PID cooling control, cooling P band 50 ~ 300% of PB, dead band -36.0 ~ 36.0% of PB |
ON-OFF |
0.1 - 90.0 ( °F ) hysteresis control ( P band = 0 ) |
P or PD |
0 - 100.0 % offset adjustment |
PID |
Fuzzy
logic modified , Proportional band 0.1 ~ 900.0°F , |
Cycle Time |
0.1 - 90.0 seconds |
Manual Control |
Heat (MV1) and Cool (MV2) |
Auto-tuning |
Cold start and warm start |
Failure Mode |
Auto-transfer to manual mode while sensor break or A-D converter damage |
Ramping Control |
0 ~ 900.0°F/minute or 0 ~ 900.0 °F/hour ramp rate |
Digital Filter |
|
Function |
First order |
Time Constant |
0, 0.2, 0.5, 1, 2, 5, 10, 20, 30, 60 seconds programmable |
Profiler |
|
Number of profiles |
9 |
Number of Segment per profile |
Profile
1,2,3,4 : 16 |
Event Outputs |
3 |
Environmental & Physical |
|
Operating Temperature |
-10°C ~ 50°C |
Storage Temperature |
-40°C ~ 60°C |
Humidity |
0 to 90 % RH ( non-condensing ) |
Altitude |
2000m maximum |
Pollution |
Degree 2 |
Insulation Resistance |
20 Mohms min. ( at 500 VDC ) |
Dielectric Strength |
2000 VAC, 50/60 Hz for 1 minute |
Vibration Resistance |
10 - 55 Hz, 10 m/s² for 2 hours |
Shock Resistance |
200 m/s² ( 20 g ) |
Moldings |
Flame retardant polycarbonate |
Dimensions |
P41
---96mm(W) X 96mm(H) X 65mm(D), 53 mm depth behind panel |
Weight |
P41
--- 250 grams |
Approval Standards |
UL
61010C-1 , CSA C22.2 No. 24-93 , |
Protective Class |
IP65 front panel with additional option, |
IP50 front panel without additional option, |
all indoor use, |
IP 20 housing and terminals with protective cover. |
EMC |
EN61326 |
Ordering Code
|
|
||||||||||||||||||
1 Power Input |
4:
90 - 264 VAC, 47-63 HZ |
||||||||||||||||||
2 Signal Input |
1:
Standard Input |
||||||||||||||||||
3 Output 1 |
0:
None |
||||||||||||||||||
4 Output 2 |
0:
None |
||||||||||||||||||
5 Output 3 |
0:
None |
||||||||||||||||||
6 Output 4 |
0: None |
||||||||||||||||||
7 Output 5 |
0:
None |
||||||||||||||||||
8 Options |
0:
Panel mount IP50 standard |
* Remark : Specifications are subject to change without prior notice